Product Specifications for Replacement Welch Allyn 72100 Rechargeable Medical Battery
| BM Part #: | BAT-72100 |
|---|---|
| Voltage: | 2.4 Volt |
| Capacity: | 750 mAh |
| Type: | NiCd |
| Width: | 1.12" (incl. tab) |
| Height: | 2.35" |
| Diameter: | 1" |
| Shipping Weight: | 0.10Lbs (1.6 oz) |
| Warranty: | 1 Year |
Product Description
This replacement battery is 100% compatible with the Welch Allyn 72100 and all compatible models. Our batteries and accessories are made with high quality parts and are guaranteed to meet or exceed the original equipment manufacturers specifications at a reduced price. All batteries are tested for 100% Quality Control Assurance.
This replacement battery includes a 1 Year Warranty to guarantee that it has no manufacturing defects.
Before using, follow these instructions:
- Fully charge battery (16 hours)
- Run battery completely down
- Fully recharge (16 hours)
- Run battery completely down
- Fully recharge (16 hours)
- Battery is ready for use
How to replace rechargeable batteries:
When a rechargeable battery will no longer accept a charge, replace as follows:
- Unscrew bottom cap.
- Note how the old battery is oriented and shake out old battery.
- Insert replacement battery with the same orientation as the battery you removed (Typically, the flat / bottom side towards the cap).
- CAUTION: Insert battery fully until seated. For convertible handles, match polarity marking with those on instrument when inserting replacement battery.
- Screw bottom cap back into place. Ensure the plastic cap is securely attached to the bottom cap. If the insulator is missing or broken, contact Welch Allyn for a new bottom cap.
For models 71000, 71010, 71020, 71050, 70700, 70710, 70720, 70750 (non-convertible, rechargeable handles with self-contained charger), insure that plastic insulator cap is intact and securely seated on spring. If missing or damaged, install a new cap before using.
DO NOT INTERCHANGE BOTTOM CAPS BETWEEN DIFFERENT MODELS OF RECHARGEABLE HANDLES. USE OF INCORRECT BOTTOM CAP MAY DAMAGE THE BATTERY OR CAUSE THE HANDLE TO OVERHEAT. BURNS MAY OCCUR FROM AN OVERHEATED HANDLE.
Cross Reference & Compatibility
NOTE REGARDING ITEMS MARKED IN RED: If you battery is longer than 1.9", please see Item # BAT-72200 instead.
- Welch-Allyn 78904585
This battery can be used in these models:
- Cardinal Medical CJB-720
- Diversified Medical N MNC720W
- *Propper 199121
- Welch-Allyn 60700
- Welch-Allyn 60713
- Welch-Allyn 617
- Welch-Allyn 617 Handles
- Welch-Allyn 70000
- Welch-Allyn 70200
- Welch-Allyn 70500
- Welch-Allyn 707
- Welch-Allyn 70700
- Welch-Allyn 70710
- Welch-Allyn 70715
- Welch-Allyn 70720
- Welch-Allyn 70750
- Welch-Allyn 70751
- Welch-Allyn 70754
- Welch-Allyn 70755
- Welch-Allyn 71205
- Welch-Allyn 71210
- Welch-Allyn 71250
- Welch-Allyn 71500
- Welch-Allyn 717
- Welch-Allyn 717 Handles
- Welch-Allyn 72000
- Welch-Allyn 72100
- Welch-Allyn 72110
- Welch-Allyn 99408
Customer Reviews
This battery is for a fifty year old Welch Allyn diagnostic set. It has the correct contacts which some aftermarket replacements lack. It works fine. Current W-A equipment uses 3.5 volts so this battery is only for the older models.
Correct fit for a vintage (> 50 year old) WA Otoscope Handle 2.4V.
Our otoscope/ophthalmoscope is at least vintage and rarely needed. We were pleased to be able to purchase a replacement batter so that it was again functional. This replacement battery fits and the ophthalmoscope now works. I hope that it remains functional for a long time.
once I identified this as the correct battery for my old Welch Allyn ophthalmoscope/otoscope, I put it in charged it up and began using it. It’s an old model-only number on it is ppl poly red circular insulator at the base of the charging prongs. I purchased it in 1978, I believe.
nice people, sent it fast.