Product Specifications for APCRBC142 Replacement Battery for APC
| BM Part #: | APCRBC142 |
|---|---|
| Voltage: | 24 Volt |
| Capacity: | 9 Ah |
| Type: | Sealed Lead Acid |
| Length: | 5.88" |
| Width: | 5.13" |
| Height: | 4.06" |
| Shipping Weight: | 12.00Lbs |
| Warranty: | 2 Year |
- This item is not eligible for free shipping.
- Direct replacement for APC RBC142 battery cartridge (also known as APCRBC142).
- Compatible with APC Smart-UPS C 1000VA models (SMC1000 series).
- 24V 9Ah sealed lead acid (SLA) battery - same specs as original APC battery.
- Compact dimensions: 5.88" x 5.13" x 4.06" (149mm x 130mm x 103mm) - exact fit for APC battery compartments.
- 2-year manufacturer warranty for reliable performance.
- Restores full UPS runtime and battery backup capacity.
- Significantly lower cost than buying a new UPS or OEM replacement cartridge.
- Professional-grade battery for servers, workstations, and network equipment.
Product Description
Affordable Alternative to APC Original Batteries
When your APC Smart-UPS C starts beeping with a "replace battery" warning or no longer provides adequate backup time during power outages, you don't need to buy an expensive OEM battery cartridge or replace the entire UPS. This APCRBC142-compatible replacement battery from WSP delivers the same 24V 9Ah capacity as the original APC battery at a fraction of the cost. It's a direct fit for APC Smart-UPS C 1000VA models, restoring full battery backup runtime and protecting your equipment from power outages and surges just like the day you bought your UPS.
Compatible with APC Smart-UPS C 1000VA Models
This replacement battery works with the following APC Smart-UPS C models that originally shipped with the RBC142/APCRBC142 battery cartridge:
Smart-UPS C 1000VA: SMC1000, SMC1000-BR, SMC1000C, SMC1000I, SMC1000I-RS, SMC1000IC, SMC1000TW
To verify compatibility, check the label on your UPS (usually on the back, bottom, or front panel) for the model number, or open the battery compartment and look for "RBC142" or "APCRBC142" marked on the existing battery. If your model isn't listed but the battery compartment says RBC142 or APCRBC142, this replacement will work.
Same Specifications as Original APC Battery
This sealed lead acid battery matches the electrical and physical specifications of the original APC RBC142/APCRBC142:
- Voltage: 24 Volts (configured as two 12V batteries in series)
- Capacity: 9 Amp-hours (Ah) at 20-hour rate
- Chemistry: Sealed Lead Acid (SLA) / Valve-Regulated Lead Acid (VRLA)
- Dimensions: 5.88" L x 5.13" W x 4.06" H (149mm x 130mm x 103mm)
- Terminal Type: F2 (Faston .250" tabs)
- Weight: Approximately 12.0 lbs (5.4 kg)
The 24V configuration (two 12V batteries wired in series) provides the higher voltage required by these Smart-UPS C models. The 9Ah capacity provides solid runtime for workstations, servers, networking equipment, and other business-critical applications. Because it uses the same sealed lead acid technology as the original, the battery is maintenance-free (no water refilling required) and safe for indoor use in offices, server rooms, data closets, or anywhere your UPS is located. The spill-proof design means it can be installed in any orientation without leaking.
Easy Installation
Replacing your UPS battery is straightforward and typically takes 10-15 minutes. Most Smart-UPS C models have a front access panel that opens to reveal the battery compartment. Simply disconnect the old battery's wire harness, slide it out, install the new battery, reconnect the harness, and close the access panel. Some models may require a screwdriver to remove the front panel, but the battery itself slides in and out without tools.
After installation, plug in your UPS and let it charge for at least 8-12 hours before relying on it for battery backup. The UPS may beep or show a "replace battery" warning initially, but this should clear once the new battery is fully charged and the UPS completes its self-test. Consult your UPS manual if the warning persists after 24 hours of charging.
When to Replace Your UPS Battery
UPS batteries typically last 3-5 years depending on usage, temperature, and how often they're discharged. Signs that your battery needs replacement include:
- UPS beeping continuously or showing a "replace battery" indicator on the front panel or management software
- Significantly reduced runtime during power outages compared to when new
- UPS failing to switch to battery power during outages
- Battery age exceeding 3-5 years, even if no obvious symptoms
- Battery self-test failures reported in UPS logs or management interface
For business-critical applications, replacing the battery proactively every 3-4 years ensures your equipment stays protected. The cost of a replacement battery is minimal compared to the potential cost of downtime, data loss, or damaged equipment from unexpected shutdowns.
2-Year Warranty
This replacement battery includes an 2-year manufacturer warranty covering defects in materials and workmanship. If the battery fails to hold a charge or exhibits manufacturing defects within the warranty period, we'll replace it at no charge. The warranty does not cover damage from misuse, physical damage, or batteries that have simply reached end-of-life due to normal aging.
Frequently Asked Questions
Is this battery as good as the original APC RBC142/APCRBC142?
Yes. This battery uses the same sealed lead acid chemistry, voltage, and capacity as the original APC RBC142/APCRBC142. It's manufactured by WSP to the same specifications and will restore your UPS to full runtime capacity. The main difference is price — third-party replacement batteries cost significantly less than APC's branded cartridges while delivering equivalent performance. We back this with an 2-year warranty.
How do I know if my UPS uses an RBC142/APCRBC142 battery?
Check your UPS model number against the compatibility list above. If your model is listed (typically an SMC1000 variant), it uses the RBC142/APCRBC142. You can also open your UPS battery compartment and look at the existing battery — if it's marked "RBC142" or "APCRBC142" or measures approximately 5.88" x 5.13" x 4.06", this replacement will fit. When in doubt, take a photo of your current battery (including any labels) and contact us for verification before ordering.
Will this work in my SMC1000 Smart-UPS C?
Yes. All SMC1000 series models (including regional variants with suffixes like -BR, -I, -IC, -TW, and -RS) use the RBC142/APCRBC142 battery, and this replacement is fully compatible. These professional-grade 1000VA Smart-UPS C units all use the same 24V 9Ah battery configuration.
Why is this battery 24V instead of 12V?
The APCRBC142 is configured as a 24V battery pack, which is achieved by wiring two 12V batteries in series inside a single housing. This higher voltage is required by Smart-UPS C 1000VA models to deliver the necessary power output for professional workstations and servers. The battery arrives pre-configured as a 24V unit, so you don't need to worry about wiring multiple batteries together — it's a direct replacement.
How much runtime will I get with this battery?
Runtime depends on the load connected to your UPS. A fully charged 9Ah battery in a Smart-UPS C 1000VA unit powering a workstation or server (approximately 400-600W load) typically provides 8-15 minutes of backup time. Lighter loads (networking equipment like routers, switches, and modems) can run for 30-60 minutes or more. Heavier loads will drain the battery faster. Check your UPS manual or APC's runtime calculator on their website for charts specific to your model and load scenarios.
Will this void my UPS warranty?
No. In the United States, the Magnuson-Moss Warranty Act prevents manufacturers from voiding warranties simply because you used a third-party replacement part. Using a compatible replacement battery will not void your APC UPS warranty. However, if you have an active warranty or service contract on your UPS and it's experiencing battery issues, contact APC first — they may replace the battery under warranty at no charge.
How long will this replacement battery last?
Under typical conditions (moderate room temperature, occasional discharge cycles), sealed lead acid UPS batteries last 3-5 years. Factors that shorten battery life include high temperatures (above 77°F/25°C), frequent deep discharges, and letting the battery sit uncharged for extended periods. To maximize lifespan, keep your UPS in a cool, well-ventilated area and plug it in continuously so the battery stays charged.
Do I need to charge the battery before installing it?
The battery ships with a partial charge but should be fully charged before relying on it for backup power. Install it in your UPS, plug in the UPS, and let it charge for 8-12 hours (or overnight) before using it for battery backup. The UPS will charge the battery automatically once connected. Some Smart-UPS C models may beep or show warnings until the battery is sufficiently charged and passes the self-test.
Can I recycle my old UPS battery?
Yes, and you should. Lead-acid batteries are highly recyclable and should never go in household trash. Most battery retailers (including auto parts stores, hardware stores, and battery specialty shops) accept used SLA batteries for recycling, often at no charge. Some municipalities also have hazardous waste collection programs that accept batteries. Check with your local recycling center or waste management authority for options in your area.
What if the replacement battery doesn't fit or work?
If you've verified your model number is on the compatibility list and the battery doesn't fit or function properly, contact us immediately. We'll work with you to resolve the issue, whether that means sending a replacement or processing a return. Common issues include incorrect model identification (some APC models look similar but use different battery sizes) or receiving a defective battery, both of which we can address quickly.
Cross Reference & Compatibility
- APC APCRBC142
This battery can be used in these models:
- APC SMC1000
- APC SMC1000-BR
- APC SMC1000C
- APC SMC1000I
- APC SMC1000I-RS
- APC SMC1000IC
- APC SMC1000TW