Brand New First Quality Factory Direct|
| Dimensions: | | Length | 2.24 inches | 57 millimeters | | Width | 0.55 inches | 14 millimeters | | Height | 1.97 inches | 50 millimeters | | Height over Terminals | 1.97 inches | 50 millimeters | | Approximate Weight | 0.20 pounds | 0.09 kilograms | | Terminals: | Wire Leads - Molex housing 5264-02 & 5263-PBT plug | | Case: | ABS Plastic | |
| Nominal Voltage: | 6 Volts (3 cell in series) | | Nominal Capacity: | | 20 hour rate | (25mA to 5.25 volts) | 0.50 AH | | 10 hour rate | (45mA to 5.25 volts) | 0.45 AH | | 5 hour rate | (80mA to 5.10 volts) | 0.40 AH | | 1 hour rate | (300mA to 4.50 volts) | 0.30 AH | | Energy Density (20 hour rate) | 1.24 Watt-hours/cubic inch | 75.2 Watt-hours/l | | Specific Energy (20 hour rate) | 15.0 Watt-hours/pound | 33.3 Watt-hours/kg | | Internal Resistance (Fully Charged Battery) | 360 milliohms (approx.) |
Replaces: 7845CV2 Alarm Battery, PA6VO.5, WP0.5-6W Charging: Cycle Applications: Limit initial current to 100mA. Charge until battery voltage (under charge)reaches 7.20 to 7.35 volts at 68� F (20� C). Hold at 7.20 to 7.35 volts until currentdrops to approximately 5mA. Battery is fully charged under these conditions, and charger shouldeither be disconnected or switched to "float" voltage. "Float" or "Stand-by Service": Hold battery across constant voltage source of 6.75 to 6.90volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. |